| Specification |
Unit |
ARC 300 |
| Input voltage |
Volt |
AC415±15% |
| Phase |
No |
3 |
| Frequency |
Hz |
50/60 |
| Max input KVA@100% duty cycle |
KVA |
9.8 |
| Open circuit voltage |
Volt |
65 |
| Welding current range |
Amps |
10-300 |
| Rated input current |
Amps |
19.5 |
| Welding current @60% duty cycle |
Amps |
300 |
| Welding current @100% duty cycle |
Amps |
240 |
| Power factor |
CosΦ |
0.94 |
| Efficiency |
% |
85 |
| Degree of protection |
Class |
IP21 |
| Insulation |
Class |
F |
| Suitable electrode diameter |
mm |
1.6 – 3.2 |
| Cooling |
Type |
Forced Air |
| Dimensions (LxWxH) |
Inch |
20x8x15 |
| Weight (approx) |
kg |
14 |